Sensing Input | Voltage 180 to 500 VAC 3 phase 3 wire
Frequency 50/60 Hz selectable |
---|---|
Power Input | Voltage 100~300 VAC 1 phase 2 wire |
Output | Voltage Max. 90 VDC @ 240 VAC input
Current Continuous 15A, Intermittent 20A for 10 sec. Resistance Min. 4 Ohm @ 35 volts output |
Volts Regulation | < ±0.5% (with 4% engine governing) |
Voltage Build-up | Residual voltage at AVR terminal > 5 VAC |
External Voltage Adjustment | ±15% with 5 K Ohm 1 watt trimmer |
Unit Power Dissipation | Max. 8 watt |
Soft Start Ramp Time | 2 sec. |
Thermal Drift | 0.03% per °C change in AVR ambient |
Under Frequency Protection | 60 Hz system presets knee point at 55 Hz
50 Hz system presets knee point at 45 Hz |
Environment | Operating Temperature : -40~65 °C
Storage Temperature : -40~85 °C Relative Humidity : Maximum 95% Vibration : 3.3G @ 100~2 KHz |
AVR Controls Functions | VOLTS : Voltage Adjustment
STAB : Stability Adjustment U/F*: To Set the U/F Knee Point (*U/F: Under Frequency Protection) |
Dimensions | 150.0 (L) x 135.0 (W) x 72.0 (H) mm |
Weight | 867 g ±2% |