<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>USB Archives - Power Systems Plus</title>
	<atom:link href="https://powersystemsplusinc.com/product-tag/usb/feed/" rel="self" type="application/rss+xml" />
	<link>https://powersystemsplusinc.com/product-tag/usb/</link>
	<description>Generator Service, Sales, Parts, &#38; Installation- Since 1999</description>
	<lastBuildDate>Wed, 01 Apr 2026 20:16:36 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://powersystemsplusinc.com/wp-content/uploads/2018/01/logofixed2-50x50.png</url>
	<title>USB Archives - Power Systems Plus</title>
	<link>https://powersystemsplusinc.com/product-tag/usb/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>DSE815 AVR Communication Interface</title>
		<link>https://powersystemsplusinc.com/product/deep-sea-electronics-dse815-avr-usb-to-rs485-converter-dse-815-0815-01/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=deep-sea-electronics-dse815-avr-usb-to-rs485-converter-dse-815-0815-01</link>
		
		<dc:creator><![CDATA[Hope Kramer]]></dc:creator>
		<pubDate>Wed, 06 Jul 2016 20:27:11 +0000</pubDate>
				<guid isPermaLink="false">https://powersystemsplusinc.com/?post_type=product&#038;p=4099</guid>

					<description><![CDATA[<h2 data-start="138" data-end="367"><strong data-start="138" data-end="176">Free Shipping</strong><br data-start="176" data-end="179" />The <strong data-start="183" data-end="193">DSE815</strong> acts as a reliable interface between your AVR and PC, using an RS485 connection to provide seamless access to AVR settings via the <strong data-start="325" data-end="352">DSE Configuration Suite</strong> PC Software.</h2>
<ul data-start="369" data-end="747">
<li data-start="369" data-end="474">
<p data-start="371" data-end="474"><strong data-start="371" data-end="397">Effortless Integration</strong>: Quick and simple connection to your AVR for configuration and monitoring.</p>
</li>
<li data-start="475" data-end="605">
<p data-start="477" data-end="605"><strong data-start="477" data-end="504">Compact and Field-Ready</strong>: Powered directly from USB, it's designed for ease of use in both workshop and field environments.</p>
</li>
<li data-start="606" data-end="747">
<p data-start="608" data-end="747"><strong data-start="608" data-end="628">Complete Control</strong>: Unlock full access to your AVR settings and optimize your generator’s performance with the DSE Configuration Suite.</p>
</li>
</ul>
<p data-start="749" data-end="894"><em><strong>Take full control of your generator’s AVR today. Order the DSE815 from Power Systems Plus and streamline your setup and maintenance process. Free shipping nationwide on the DSE 815 Communication Interface.</strong></em></p>
<p>The post <a href="https://powersystemsplusinc.com/product/deep-sea-electronics-dse815-avr-usb-to-rs485-converter-dse-815-0815-01/">DSE815 AVR Communication Interface</a> appeared first on <a href="https://powersystemsplusinc.com">Power Systems Plus</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h1>DSE815 AVR Communication Interface For Sale in Portland, OR</h1>
<p>The DSE815 acts as an interface between the AVR and a PC through an RS485 connection, enabling access to the AVR settings. It works seamlessly with the DSE Configuration Suite PC Software for easy configuration and monitoring. Order your 815 interface today from Power Systems Plus and enhance your AVR management!</p>
<div class="description"></div>
<div></div>
<div>Additional Specifications:</div>
<div class="sizing">
<p><b>DIMENSIONS<br />
</b>90 mm x 50 mm x 25 mm<br />
3.5&#8243; x 2&#8243; x 1&#8243;</p>
<p>Specification</p>
</div>
<p><b>DC SUPPLY<br />
</b>Powered from the USB connection</p>
<p><b>OPERATING TEMPERATURE RANGE<br />
</b>-30 ºC to +70 ºC<br />
-22 °F to +158 °F</p>
<p>The post <a href="https://powersystemsplusinc.com/product/deep-sea-electronics-dse815-avr-usb-to-rs485-converter-dse-815-0815-01/">DSE815 AVR Communication Interface</a> appeared first on <a href="https://powersystemsplusinc.com">Power Systems Plus</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DSE857 USB to RS485 Communications Device DSE 857 #0857-01</title>
		<link>https://powersystemsplusinc.com/product/deep-sea-electronics-dse857-usb-to-rs485-communications-device-dse-857/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=deep-sea-electronics-dse857-usb-to-rs485-communications-device-dse-857</link>
		
		<dc:creator><![CDATA[Hope Kramer]]></dc:creator>
		<pubDate>Thu, 10 Sep 2015 21:36:34 +0000</pubDate>
				<guid isPermaLink="false">https://powersystemsplusinc.com/product/deep-sea-electronics-dse857-usb-to-rs485-communications-device-dse-857/</guid>

					<description><![CDATA[<p><strong>Deep Sea Electronics DSE857 USB to RS485 Communications Device</strong></p>
<p>The DSE857 communications device allows monitoring of a single DSE controller with USB connectivity by converting it to an RS485 connection. To achieve this the DSE857 connects to an RS485 MODBUS RTU master over 1.2km away. The MODBUS RTU master can be an external PLC, Building Management System (BMS) or a Windows PC running the DSE Configuration Suite Software.</p>
<p>Works with:</p>
<p><strong>Auto Start:</strong></p>
<p>DSEL401MKII/DSE<strong>4310</strong>/DSE<strong>4410</strong>/DSE<strong>4510</strong>/DSE<strong>4610</strong>/DSE<strong>6010</strong>MKII/</p>
<p>DSE<strong>6110</strong>/DSE<strong>6610</strong>/DSE<strong>7110</strong> MKII/DSE<strong>7210</strong>/DSE<strong>7310</strong></p>
<p><strong>Auto Mains (Utility) Failure:</strong></p>
<p>DSE<strong>4320</strong>/DSE<strong>4420</strong>/DSE<strong>4520</strong>/DSE<strong>4620</strong>/DSE<strong>6020</strong>/DSE<strong>6120</strong>MKII/</p>
<p>DSE<strong>6620</strong>/DSE<strong>7120</strong>MKII/DSE<strong>7220</strong>/DSE<strong>7320</strong></p>
<p><strong>OVERALL SIZE</strong></p>
<p>35 mm x 97 mm x 102 mm (1.4” x 3.8” x 4.0”)</p>
<p><strong>WEIGHT</strong></p>
<p>0.16kg</p>
<p><strong><u>Key Features and Benefits:</u></strong></p>
<ul>
<li>Converts a USB port to an RS485 port.</li>
<li>Remote control &#38; monitoring for all connected modules.</li>
<li>Access permission settings.</li>
<li>Supports MODBUS RTU using the RS485 port.</li>
<li>Full building management system integration.</li>
<li>Firmware upgradeable.</li>
<li>DIN rail mount.</li>
</ul>
<p>&#160;</p>
<p>The post <a href="https://powersystemsplusinc.com/product/deep-sea-electronics-dse857-usb-to-rs485-communications-device-dse-857/">DSE857 USB to RS485 Communications Device DSE 857 #0857-01</a> appeared first on <a href="https://powersystemsplusinc.com">Power Systems Plus</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Deep Sea Electronics DSE857 USB to RS485 Communications Device</strong></p>
<p>The DSE857 communications device allows monitoring of a single DSE controller with USB connectivity by converting it to an RS485 connection. To achieve this the DSE857 connects to an RS485 MODBUS RTU master over 1.2km away. The MODBUS RTU master can be an external PLC, Building Management System (BMS) or a Windows PC running the DSE Configuration Suite Software.</p>
<p>Works with:</p>
<p><strong>Auto Start:</strong></p>
<p>DSEL401MKII/DSE<strong>4310</strong>/DSE<strong>4410</strong>/DSE<strong>4510</strong>/DSE<strong>4610</strong>/DSE<strong>6010</strong>MKII/</p>
<p>DSE<strong>6110</strong>/DSE<strong>6610</strong>/DSE<strong>7110</strong> MKII/DSE<strong>7210</strong>/DSE<strong>7310</strong></p>
<p><strong>Auto Mains (Utility) Failure:</strong></p>
<p>DSE<strong>4320</strong>/DSE<strong>4420</strong>/DSE<strong>4520</strong>/DSE<strong>4620</strong>/DSE<strong>6020</strong>/DSE<strong>6120</strong>MKII/</p>
<p>DSE<strong>6620</strong>/DSE<strong>7120</strong>MKII/DSE<strong>7220</strong>/DSE<strong>7320</strong></p>
<p><strong>OVERALL SIZE</strong></p>
<p>35 mm x 97 mm x 102 mm (1.4” x 3.8” x 4.0”)</p>
<p><strong>WEIGHT</strong></p>
<p>0.16kg</p>
<p><strong><u>Key Features and Benefits:</u></strong></p>
<ul>
<li>Converts a USB port to an RS485 port.</li>
<li>Remote control &amp; monitoring for all connected modules.</li>
<li>Access permission settings.</li>
<li>Supports MODBUS RTU using the RS485 port.</li>
<li>Full building management system integration.</li>
<li>Firmware upgradeable.</li>
<li>DIN rail mount.</li>
</ul>
<h2><strong>DC SUPPLY</strong></h2>
<p><strong>CONTINUOUS VOLTAGE RATING</strong></p>
<p>8 V to 35 V Continuous</p>
<p><strong>CRANKING DROPOUTS</strong></p>
<p>Able to survive 0 V for 100 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking.</p>
<p><strong>MAXIMUM OPERATING CURRENT</strong></p>
<p>123 mA at 12 V</p>
<p>71 mA at 24 V</p>
<p><strong>MAXIMUM STANDBY CURRENT</strong></p>
<p>104 mA at 12 V</p>
<p>63 mA at 24 V</p>
<h2><strong>COMMUNICATIONS</strong></h2>
<p>USB (Single DSE Controller)</p>
<p>RS485</p>
<p>&nbsp;</p>
<p>The post <a href="https://powersystemsplusinc.com/product/deep-sea-electronics-dse857-usb-to-rs485-communications-device-dse-857/">DSE857 USB to RS485 Communications Device DSE 857 #0857-01</a> appeared first on <a href="https://powersystemsplusinc.com">Power Systems Plus</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DSE855 DSENet USB to Ethernet Communications Device DSE 855 #0855-01</title>
		<link>https://powersystemsplusinc.com/product/deep-sea-electronics-dse855-dsenet-usb-to-ethernet-communications-device-dse-855/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=deep-sea-electronics-dse855-dsenet-usb-to-ethernet-communications-device-dse-855</link>
		
		<dc:creator><![CDATA[Hope Kramer]]></dc:creator>
		<pubDate>Tue, 25 Aug 2015 18:09:47 +0000</pubDate>
				<guid isPermaLink="false">https://powersystemsplusinc.com/product/deep-sea-electronics-dse855-dsenet-usb-to-ethernet-communications-device-dse-855/</guid>

					<description><![CDATA[<div class="flex flex-col text-sm pb-25">
<article class="text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [&#38;:has([data-writing-block])&#62;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]" dir="auto" tabindex="-1" data-turn-id="request-WEB:767dc87a-1d6a-41fc-949e-8615f7712be0-33" data-testid="conversation-turn-68" data-scroll-anchor="true" data-turn="assistant">
<div class="text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)">
<div class="[--thread-content-max-width:40rem] @w-lg/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn" tabindex="-1">
<div class="flex max-w-full flex-col gap-4 grow">
<div class="min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+&#38;]:mt-1" dir="auto" data-message-author-role="assistant" data-message-id="65b70e3b-2a7a-4b73-96b3-4bea6c788f39" data-message-model-slug="gpt-5-3">
<div class="flex w-full flex-col gap-1 empty:hidden">
<div class="markdown prose dark:prose-invert w-full wrap-break-word dark markdown-new-styling">
<p data-start="0" data-end="220">The <strong data-start="4" data-end="73">Deep Sea Electronics DSE855 USB to Ethernet Communications Device</strong> converts a USB connection on a compatible DSE controller into Ethernet, allowing remote generator monitoring and control over LAN or WAN networks.</p>
<p data-start="222" data-end="587">• Converts a USB connection on a DSE controller to Ethernet for network access<br data-start="300" data-end="303" />• Built-in web server for remote monitoring through a standard web browser<br data-start="377" data-end="380" data-is-only-node="" />• Supports MODBUS TCP for building management system integration<br data-start="444" data-end="447" />• Monitor generator status, alarms, and data from multiple locations<br data-start="515" data-end="518" />• Compact DIN rail mount design for easy control panel installation</p>
<p data-start="589" data-end="729" data-is-last-node="" data-is-only-node="">Enable reliable remote monitoring for your generator controller—order the DSE855 online or message us to confirm availability and lead time.</p>
</div>
</div>
</div>
</div>
</div>
</div>
</article>
</div>
<p>The post <a href="https://powersystemsplusinc.com/product/deep-sea-electronics-dse855-dsenet-usb-to-ethernet-communications-device-dse-855/">DSE855 DSENet USB to Ethernet Communications Device DSE 855 #0855-01</a> appeared first on <a href="https://powersystemsplusinc.com">Power Systems Plus</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 data-section-id="15ejb08" data-start="634" data-end="702">Deep Sea Electronics DSE855 USB to Ethernet Communications Device</h2>
<p data-start="704" data-end="1086">The DSE855 communications device converts a USB connection on a compatible Deep Sea Electronics generator controller into an Ethernet connection, allowing remote monitoring and control over a LAN or WAN network. Using its built-in web server or MODBUS TCP protocol, operators can access generator data, alarms, and system status from remote locations through a standard web browser.</p>
<p data-start="1088" data-end="1182">To enable global access, the on-site router must be configured to allow external connectivity.</p>
<hr data-start="1184" data-end="1187" />
<h2 data-section-id="1onepnw" data-start="1189" data-end="1214">Compatible Controllers</h2>
<h3 data-section-id="1os9v0m" data-start="1216" data-end="1242">Auto Start Controllers</h3>
<p data-start="1243" data-end="1364">DSE401 MKII<br data-start="1254" data-end="1257" />DSE4310<br data-start="1264" data-end="1267" />DSE4410<br data-start="1274" data-end="1277" />DSE4510<br data-start="1284" data-end="1287" />DSE4610<br data-start="1294" data-end="1297" />DSE6010 MKII<br data-start="1309" data-end="1312" />DSE6110<br data-start="1319" data-end="1322" />DSE6610<br data-start="1329" data-end="1332" />DSE7110 MKII<br data-start="1344" data-end="1347" />DSE7210<br data-start="1354" data-end="1357" />DSE7310</p>
<h3 data-section-id="18hz5b3" data-start="1366" data-end="1410">Auto Mains (Utility) Failure Controllers</h3>
<p data-start="1411" data-end="1518">DSE4320<br data-start="1418" data-end="1421" />DSE4420<br data-start="1428" data-end="1431" />DSE4520<br data-start="1438" data-end="1441" />DSE4620<br data-start="1448" data-end="1451" />DSE6020<br data-start="1458" data-end="1461" />DSE6120 MKII<br data-start="1473" data-end="1476" />DSE6620<br data-start="1483" data-end="1486" />DSE7120 MKII<br data-start="1498" data-end="1501" />DSE7220<br data-start="1508" data-end="1511" />DSE7320</p>
<hr data-start="1520" data-end="1523" />
<h2 data-section-id="1ma7m6t" data-start="1525" data-end="1540">Key Features</h2>
<p data-start="1542" data-end="1971">• Converts a USB connection to Ethernet for remote generator monitoring<br data-start="1613" data-end="1616" />• Built-in web server for browser-based configuration and access<br data-start="1680" data-end="1683" />• Supports MODBUS TCP communication via Ethernet<br data-start="1731" data-end="1734" />• Allows remote monitoring from up to four locations simultaneously<br data-start="1801" data-end="1804" />• Compatible with building management systems (BMS)<br data-start="1855" data-end="1858" />• Firmware upgradeable for long-term system compatibility<br data-start="1915" data-end="1918" />• Compact DIN rail mount design for easy installation</p>
<hr data-start="1973" data-end="1976" />
<h2 data-section-id="7q4hfq" data-start="1978" data-end="1991">Dimensions</h2>
<p data-start="1993" data-end="2053">Overall Size<br data-start="2005" data-end="2008" />35 mm × 97 mm × 102 mm<br data-start="2030" data-end="2033" />(1.4&#8243; × 3.8&#8243; × 4.0&#8243;)</p>
<p data-start="2055" data-end="2071">Weight<br data-start="2061" data-end="2064" />0.16 kg</p>
<hr data-start="2073" data-end="2076" />
<h2 data-section-id="xggplx" data-start="2078" data-end="2106">Electrical Specifications</h2>
<h3 data-section-id="1k4ju6q" data-start="2108" data-end="2121">DC Supply</h3>
<p data-start="2123" data-end="2162">Continuous Voltage Rating<br data-start="2148" data-end="2151" />8 V to 35 V</p>
<p data-start="2164" data-end="2284">Cranking Dropouts<br data-start="2181" data-end="2184" />Able to survive 0 V for 100 mS provided supply was at least 10 V before dropout and recovers to 5 V.</p>
<p data-start="2286" data-end="2344">Maximum Operating Current<br data-start="2311" data-end="2314" />123 mA at 12 V<br data-start="2328" data-end="2331" />71 mA at 24 V</p>
<p data-start="2346" data-end="2402">Maximum Standby Current<br data-start="2369" data-end="2372" />104 mA at 12 V<br data-start="2386" data-end="2389" />63 mA at 24 V</p>
<hr data-start="2404" data-end="2407" />
<h3 data-section-id="4fz19x" data-start="2409" data-end="2427">Communications</h3>
<p data-start="2429" data-end="2467">USB (Single DSE Controller)<br data-start="2456" data-end="2459" />Ethernet</p>
<p data-start="2429" data-end="2467">
<p data-start="2429" data-end="2467">Order online or message us before ordering to confirm availability and lead time.</p>
<p>The post <a href="https://powersystemsplusinc.com/product/deep-sea-electronics-dse855-dsenet-usb-to-ethernet-communications-device-dse-855/">DSE855 DSENet USB to Ethernet Communications Device DSE 855 #0855-01</a> appeared first on <a href="https://powersystemsplusinc.com">Power Systems Plus</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>