<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>DSE4620 Archives - Power Systems Plus</title>
	<atom:link href="https://powersystemsplusinc.com/product-tag/dse4620/feed/" rel="self" type="application/rss+xml" />
	<link>https://powersystemsplusinc.com/product-tag/dse4620/</link>
	<description>Generator Service, Sales, Parts, &#38; Installation- Since 1999</description>
	<lastBuildDate>Mon, 27 Apr 2026 21:31:45 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://powersystemsplusinc.com/wp-content/uploads/2018/01/logofixed2-50x50.png</url>
	<title>DSE4620 Archives - Power Systems Plus</title>
	<link>https://powersystemsplusinc.com/product-tag/dse4620/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>DSE4620 Auto Mains (Utility) Failure Control Module</title>
		<link>https://powersystemsplusinc.com/product/deep-sea-electronics-dse4620-auto-mains-failure-control-module-rtc-dse-4620/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=deep-sea-electronics-dse4620-auto-mains-failure-control-module-rtc-dse-4620</link>
		
		<dc:creator><![CDATA[Hope Kramer]]></dc:creator>
		<pubDate>Fri, 28 Aug 2015 21:33:56 +0000</pubDate>
				<guid isPermaLink="false">https://powersystemsplusinc.com/product/deep-sea-electronics-dse4620-auto-mains-failure-control-module-rtc-dse-4620/</guid>

					<description><![CDATA[<p data-start="337" data-end="502">The DSE4620 Auto Mains Failure Control Module automatically starts standby generators during power outages while providing advanced engine monitoring and protection.</p>
<p data-start="504" data-end="529"><strong data-start="504" data-end="529">Best-Selling Features</strong></p>
<p data-start="531" data-end="878">• Back-lit icon LCD display for clear system status and generator information<br data-start="608" data-end="611" />• 3-phase generator and mains sensing for accurate power monitoring<br data-start="678" data-end="681" />• Generator power measurement (kW, kVA, kVAr, power factor)<br data-start="740" data-end="743" />• Magnetic pick-up speed sensing with engine protection features<br data-start="807" data-end="810" />• Compatible with DSE Configuration Suite PC software for easy setup</p>
<p data-start="488" data-end="625"><strong>The DSE 4620 Auto Mains (Utility) Failure Control Module is now Obsolete. The direct replacement is the DSE G4500. </strong></p>
<p>The post <a href="https://powersystemsplusinc.com/product/deep-sea-electronics-dse4620-auto-mains-failure-control-module-rtc-dse-4620/">DSE4620 Auto Mains (Utility) Failure Control Module</a> appeared first on <a href="https://powersystemsplusinc.com">Power Systems Plus</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h1>DSE4620 Auto Mains (Utility) Failure Control Module For Sale in Portland, Oregon</h1>
<p data-start="611" data-end="955">The <strong data-start="615" data-end="673">Deep Sea Electronics DSE4620 Auto Start Control Module</strong> is a compact Auto Mains (Utility) Failure control module designed to automatically start and stop standby generators during a utility power outage. The controller provides advanced engine monitoring, generator protection, and power measurement in a compact panel-mounted enclosure.</p>
<hr data-start="957" data-end="960" />
<h2 data-section-id="1ma7m6t" data-start="962" data-end="977">Key Features</h2>
<p data-start="979" data-end="1571">• Back-lit icon LCD display for clear generator status and alarms<br data-start="1044" data-end="1047" />• 3-phase generator and mains sensing for accurate power monitoring<br data-start="1114" data-end="1117" />• Generator and load power monitoring (kW, kVA, kVAr, power factor)<br data-start="1184" data-end="1187" />• Generator overload protection to safeguard engine performance<br data-start="1250" data-end="1253" />• Magnetic pick-up speed sensing for precise engine monitoring<br data-start="1315" data-end="1318" />• Configurable inputs and outputs for flexible installation<br data-start="1377" data-end="1380" />• Battery voltage monitoring and engine protection features<br data-start="1439" data-end="1442" />• Event log storing up to 50 alarms and operational events<br data-start="1500" data-end="1503" />• Compatible with DSE Configuration Suite PC software for easy setup</p>
<hr data-start="1573" data-end="1576" />
<h2 data-section-id="7q4hfq" data-start="1578" data-end="1591">Dimensions</h2>
<p data-start="1593" data-end="1658"><strong data-start="1593" data-end="1609">Overall Size</strong><br data-start="1609" data-end="1612" />140 mm × 113 mm × 43 mm<br data-start="1635" data-end="1638" />(5.5&#8243; × 4.4&#8243; × 1.5&#8243;)</p>
<p data-start="1660" data-end="1714"><strong data-start="1660" data-end="1681">Panel Cutout Size</strong><br data-start="1681" data-end="1684" />118 mm × 92 mm<br data-start="1698" data-end="1701" />(4.6&#8243; × 3.6&#8243;)</p>
<p data-start="1716" data-end="1759"><strong data-start="1716" data-end="1743">Maximum Panel Thickness</strong><br data-start="1743" data-end="1746" />8.0 mm (0.3&#8243;)</p>
<p data-start="1761" data-end="1781"><strong data-start="1761" data-end="1771">Weight</strong><br data-start="1771" data-end="1774" />0.28 kg</p>
<hr data-start="1783" data-end="1786" />
<h2 data-section-id="xggplx" data-start="1788" data-end="1816">Electrical Specifications</h2>
<h3 data-section-id="1k4ju6q" data-start="1818" data-end="1831">DC Supply</h3>
<p data-start="1833" data-end="1872">Continuous Voltage Rating<br data-start="1858" data-end="1861" />8 V to 35 V</p>
<p data-start="1874" data-end="1993">Cranking Dropouts<br data-start="1891" data-end="1894" />Able to survive 0 V for 50 mS provided supply was at least 10 V before dropout and recovers to 5 V.</p>
<p data-start="1995" data-end="2052">Maximum Operating Current<br data-start="2020" data-end="2023" />85 mA at 12 V<br data-start="2036" data-end="2039" />96 mA at 24 V</p>
<p data-start="2054" data-end="2109">Maximum Standby Current<br data-start="2077" data-end="2080" />51 mA at 12 V<br data-start="2093" data-end="2096" />47 mA at 24 V</p>
<p data-start="2111" data-end="2164">Maximum Sleep Current<br data-start="2132" data-end="2135" />35 mA at 12 V<br data-start="2148" data-end="2151" />32 mA at 24 V</p>
<p data-start="2166" data-end="2201">Maximum Deep Sleep Current<br data-start="2192" data-end="2195" />&lt;10 uA</p>
<hr data-start="2203" data-end="2206" />
<h3 data-section-id="fd187z" data-start="2208" data-end="2227">Mains (Utility)</h3>
<p data-start="2229" data-end="2295">Voltage Range<br data-start="2242" data-end="2245" />15 V to 415 V AC (Ph-N)<br data-start="2268" data-end="2271" />26 V to 719 V AC (Ph-Ph)</p>
<p data-start="2297" data-end="2330">Frequency Range<br data-start="2312" data-end="2315" />3.5 Hz to 75 Hz</p>
<hr data-start="2332" data-end="2335" />
<h3 data-section-id="kchn5q" data-start="2337" data-end="2358">Generator Sensing</h3>
<p data-start="2360" data-end="2426">Voltage Range<br data-start="2373" data-end="2376" />15 V to 415 V AC (Ph-N)<br data-start="2399" data-end="2402" />26 V to 719 V AC (Ph-Ph)</p>
<p data-start="2428" data-end="2461">Frequency Range<br data-start="2443" data-end="2446" />3.5 Hz to 75 Hz</p>
<hr data-start="2463" data-end="2466" />
<h3 data-section-id="et0zxm" data-start="2468" data-end="2479">Outputs</h3>
<p data-start="2481" data-end="2530">Fuel Output (A)<br data-start="2496" data-end="2499" />10 A short term, 5 A continuous</p>
<p data-start="2532" data-end="2582">Start Output (B)<br data-start="2548" data-end="2551" />10 A short term, 5 A continuous</p>
<p data-start="2584" data-end="2634">Auxiliary Outputs (C–F)<br data-start="2607" data-end="2610" />2 A DC at supply voltage</p>
<hr data-start="2636" data-end="2639" />
<h3 data-section-id="fbu08x" data-start="2641" data-end="2661">Magnetic Pick-Up</h3>
<p data-start="2663" data-end="2693">Voltage Range<br data-start="2676" data-end="2679" />±0.5 V to 70 V</p>
<p data-start="2695" data-end="2724">Maximum Frequency<br data-start="2712" data-end="2715" />10,000 Hz</p>
<hr data-start="2726" data-end="2729" />
<h2 data-section-id="a2j95g" data-start="2731" data-end="2746">Availability</h2>
<p data-start="2748" data-end="2867">Order the DSE4620 Auto Mains Failure Control Module online or message us to confirm availability and current lead time.</p>