<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>DSE4610 Archives - Power Systems Plus</title>
	<atom:link href="https://powersystemsplusinc.com/product-tag/dse4610/feed/" rel="self" type="application/rss+xml" />
	<link>https://powersystemsplusinc.com/product-tag/dse4610/</link>
	<description>Generator Service, Sales, Parts, &#38; Installation- Since 1999</description>
	<lastBuildDate>Mon, 27 Apr 2026 21:34:59 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://powersystemsplusinc.com/wp-content/uploads/2018/01/logofixed2-50x50.png</url>
	<title>DSE4610 Archives - Power Systems Plus</title>
	<link>https://powersystemsplusinc.com/product-tag/dse4610/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>DSE4610 Auto Start Control Module RTC DSE 4610 #4610-03</title>
		<link>https://powersystemsplusinc.com/product/deep-sea-electronics-dse4610-auto-start-control-module-rtc-dse-4610/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=deep-sea-electronics-dse4610-auto-start-control-module-rtc-dse-4610</link>
		
		<dc:creator><![CDATA[Hope Kramer]]></dc:creator>
		<pubDate>Fri, 28 Aug 2015 21:01:25 +0000</pubDate>
				<guid isPermaLink="false">https://powersystemsplusinc.com/product/deep-sea-electronics-dse4610-auto-start-control-module-rtc-dse-4610/</guid>

					<description><![CDATA[<p data-start="247" data-end="404">The <strong data-start="251" data-end="263">DSE 4610</strong> is a compact auto start generator controller designed for reliable engine control, monitoring, and protection in single genset applications.</p>
<p data-start="406" data-end="667">It features a clear backlit LCD display, 3-phase generator sensing, and full engine monitoring including speed, battery voltage, and load performance. With configurable inputs and outputs, it offers flexible integration across a wide range of generator systems.</p>
<h3 data-section-id="1iz91iu" data-start="669" data-end="685">Key Features</h3>
<ul data-start="686" data-end="1065">
<li data-section-id="2ilh42" data-start="686" data-end="737">Backlit LCD display for clear system visibility</li>
<li data-section-id="1s6lwqp" data-start="738" data-end="767">3-phase generator sensing</li>
<li data-section-id="rbs9xn" data-start="768" data-end="831">Generator and load monitoring (kW, kVA, kVAr, power factor)</li>
<li data-section-id="1gj9rim" data-start="832" data-end="875">Engine protection and overload shutdown</li>
<li data-section-id="fkt7a7" data-start="876" data-end="937">Configurable inputs and outputs for flexible installation</li>
<li data-section-id="daf0lq" data-start="938" data-end="971">Magnetic pickup speed sensing</li>
<li data-section-id="1kbtatu" data-start="972" data-end="1011">Event logging and fault diagnostics</li>
<li data-section-id="sdsxau" data-start="1012" data-end="1065">Programmable via DSE Configuration Suite software</li>
</ul>
<h3 data-section-id="1yl5694" data-start="1067" data-end="1085">Specifications</h3>
<ul data-start="1086" data-end="1202">
<li data-section-id="1mm2bhy" data-start="1086" data-end="1119">Size: 140 mm x 113 mm x 43 mm</li>
<li data-section-id="359pc3" data-start="1120" data-end="1152">Panel Cutout: 118 mm x 92 mm</li>
<li data-section-id="9hgn7i" data-start="1153" data-end="1182">Max Panel Thickness: 8 mm</li>
<li data-section-id="ny6x3e" data-start="1183" data-end="1202">Weight: 0.28 kg</li>
</ul>
<hr data-start="1204" data-end="1207" />
<h2 data-section-id="155unp6" data-start="1209" data-end="1252"><span role="text">🔄 <strong data-start="1215" data-end="1252">Important: This Model is Obsolete</strong></span></h2>
<p data-start="1254" data-end="1298">The <strong data-start="1258" data-end="1297">DSE 4610 is no longer in production</strong>.</p>
<p data-start="1300" data-end="1441">The direct replacement is the <strong data-start="1330" data-end="1364">DSE G4500 Generator Controller</strong>, offering improved diagnostics, modern compatibility, and long-term support.</p>
<p>The post <a href="https://powersystemsplusinc.com/product/deep-sea-electronics-dse4610-auto-start-control-module-rtc-dse-4610/">DSE4610 Auto Start Control Module RTC DSE 4610 #4610-03</a> appeared first on <a href="https://powersystemsplusinc.com">Power Systems Plus</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 data-section-id="n2l746" data-start="239" data-end="289"><span role="text"><strong data-start="242" data-end="289">DSE 4610 Auto Start Control Module For Sale</strong></span></h2>
<p data-start="291" data-end="448">The <strong data-start="295" data-end="307">DSE 4610</strong> is a compact auto start generator controller designed for reliable engine control, monitoring, and protection in single genset applications.</p>
<p data-start="450" data-end="650">Built with a clear backlit LCD display and flexible configuration options, it provides accurate system monitoring and dependable automatic start functionality across a wide range of generator systems.</p>
<hr data-start="652" data-end="655" />
<h3 data-section-id="1efomr0" data-start="657" data-end="676">🔧 Key Features</h3>
<ul data-start="677" data-end="1128">
<li data-section-id="1q377zk" data-start="677" data-end="724">Backlit LCD display for clear system status</li>
<li data-section-id="1s6lwqp" data-start="725" data-end="754">3-phase generator sensing</li>
<li data-section-id="177c3wm" data-start="755" data-end="816">Generator &amp; load monitoring (kW, kVA, kVAr, power factor)</li>
<li data-section-id="1gj9rim" data-start="817" data-end="860">Engine protection and overload shutdown</li>
<li data-section-id="fkt7a7" data-start="861" data-end="922">Configurable inputs and outputs for flexible installation</li>
<li data-section-id="114pbmb" data-start="923" data-end="973">Fuel and crank outputs for automatic operation</li>
<li data-section-id="daf0lq" data-start="974" data-end="1007">Magnetic pickup speed sensing</li>
<li data-section-id="1jt6jhn" data-start="1008" data-end="1038">Battery voltage monitoring</li>
<li data-section-id="17s4qw2" data-start="1039" data-end="1074">Event logging (up to 50 events)</li>
<li data-section-id="sdsxau" data-start="1075" data-end="1128">Programmable via DSE Configuration Suite software</li>
</ul>
<hr data-start="1130" data-end="1133" />
<h3 data-section-id="y8etb9" data-start="1135" data-end="1156">📐 Specifications</h3>
<ul data-start="1157" data-end="1289">
<li data-section-id="9tzq9i" data-start="1157" data-end="1194"><strong data-start="1159" data-end="1168">Size:</strong> 140 mm x 113 mm x 43 mm</li>
<li data-section-id="13gp3er" data-start="1195" data-end="1231"><strong data-start="1197" data-end="1214">Panel Cutout:</strong> 118 mm x 92 mm</li>
<li data-section-id="5xo7lq" data-start="1232" data-end="1265"><strong data-start="1234" data-end="1258">Max Panel Thickness:</strong> 8 mm</li>
<li data-section-id="tbirgq" data-start="1266" data-end="1289"><strong data-start="1268" data-end="1279">Weight:</strong> 0.28 kg</li>
</ul>
<hr data-start="1291" data-end="1294" />
<h3 data-section-id="149xzh3" data-start="1296" data-end="1326">⚡ Electrical &amp; Performance</h3>
<ul data-start="1327" data-end="1577">
<li data-section-id="1c5lyj0" data-start="1327" data-end="1374"><strong data-start="1329" data-end="1348">Supply Voltage:</strong> 8V to 35V DC continuous</li>
<li data-section-id="19ly51q" data-start="1375" data-end="1453"><strong data-start="1377" data-end="1398">Cranking Dropout:</strong> Survives 0V for 50 ms (no internal battery required)</li>
<li data-section-id="4kxf1d" data-start="1454" data-end="1516"><strong data-start="1456" data-end="1478">Operating Current:</strong>
<ul data-start="1483" data-end="1516">
<li data-section-id="97cfi4" data-start="1483" data-end="1498">85 mA @ 12V</li>
<li data-section-id="nnaeaj" data-start="1501" data-end="1516">96 mA @ 24V</li>
</ul>
</li>
<li data-section-id="jzutqm" data-start="1517" data-end="1577"><strong data-start="1519" data-end="1539">Standby Current:</strong>
<ul data-start="1544" data-end="1577">
<li data-section-id="auj6np" data-start="1544" data-end="1559">51 mA @ 12V</li>
<li data-section-id="nfsj93" data-start="1562" data-end="1577">47 mA @ 24V</li>
</ul>
</li>
</ul>
<hr data-start="1579" data-end="1582" />
<h3 data-section-id="u8jsnv" data-start="1584" data-end="1598">🔌 Outputs</h3>
<ul data-start="1599" data-end="1736">
<li data-section-id="1ckskta" data-start="1599" data-end="1649"><strong data-start="1601" data-end="1617">Fuel Output:</strong> 10A short term, 5A continuous</li>
<li data-section-id="1tjbjpg" data-start="1650" data-end="1701"><strong data-start="1652" data-end="1669">Start Output:</strong> 10A short term, 5A continuous</li>
<li data-section-id="nhgbie" data-start="1702" data-end="1736"><strong data-start="1704" data-end="1728">Aux Outputs (C &amp; D):</strong> 2A DC</li>
</ul>
<hr data-start="1738" data-end="1741" />
<h3 data-section-id="7vxzjb" data-start="1743" data-end="1779">⚙️ Generator &amp; Engine Monitoring</h3>
<ul data-start="1780" data-end="1993">
<li data-section-id="1asmmai" data-start="1780" data-end="1866"><strong data-start="1782" data-end="1800">Voltage Range:</strong>
<ul data-start="1805" data-end="1866">
<li data-section-id="1cc1dh5" data-start="1805" data-end="1835">15–415V (Phase to Neutral)</li>
<li data-section-id="1j8j2zw" data-start="1838" data-end="1866">26–719V (Phase to Phase)</li>
</ul>
</li>
<li data-section-id="1tv4vx4" data-start="1867" data-end="1907"><strong data-start="1869" data-end="1889">Frequency Range:</strong> 3.5 Hz to 75 Hz</li>
<li data-section-id="1rt0m7d" data-start="1908" data-end="1993"><strong data-start="1910" data-end="1930">Magnetic Pickup:</strong>
<ul data-start="1935" data-end="1993">
<li data-section-id="18rya8m" data-start="1935" data-end="1960">Voltage: ±0.5V to 70V</li>
<li data-section-id="g7kddz" data-start="1963" data-end="1993">Frequency: up to 10,000 Hz</li>
</ul>
</li>
</ul>
<hr data-start="1995" data-end="1998" />
<h2 data-section-id="155unp6" data-start="2000" data-end="2043"><span role="text">🔄 <strong data-start="2006" data-end="2043">Important: This Model is Obsolete</strong></span></h2>
<p data-start="2045" data-end="2115">The <strong data-start="2049" data-end="2114">DSE 4610 is no longer in production and has been discontinued</strong>.</p>
<p data-start="2117" data-end="2263">The recommended replacement is the <strong data-start="2152" data-end="2186">DSE G4500 Generator Controller</strong>, offering improved diagnostics, modern compatibility, and long-term support.</p>
<p>The post <a href="https://powersystemsplusinc.com/product/deep-sea-electronics-dse4610-auto-start-control-module-rtc-dse-4610/">DSE4610 Auto Start Control Module RTC DSE 4610 #4610-03</a> appeared first on <a href="https://powersystemsplusinc.com">Power Systems Plus</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
